CISCO Refurbished
- Manufacturer
- CISCO
- Condition
- Refurbished
- Lead Time
- 2-3 days
- Availability
- Not In Stock
Description
The 800-36608-01 is a product offered by CISCO, a global technology solutions provider. This product is a 48 port gigabit Ethernet switch, designed for small to medium-sized businesses. It is ideal for use in network environments where high-speed data transfer is a priority.The 800-36608-01 switch offers various features such as advanced Quality of Service (QoS) settings, which prioritize the delivery of critical network traffic to ensure optimal performance. It also supports VLAN segregation, allowing for easier network management and increased security.Furthermore, this product is easy to set up and manage, with an intuitive web interface for configuration and monitoring. It also comes with a limited lifetime warranty, providing customers with peace of mind and confidence in the product’s quality.Overall, the 800-36608-01 by CISCO is a powerful and reliable option for businesses needing to upgrade their network infrastructure to cope with increasing data demands.
- Part Code
- ASR9K-DC-PEM-V2
- Description
- ASR9K DC Power Entry Module Version 2
- Manufacturer
- CISCO
- End of Hardware Support
- Yes
- End of Sale
- Yes
- End of Life
- Yes
Hardware Available for Cisco ASR 9000 & ASR 9900 Series
Expand
Hardware Available for Cisco ASR 9000 & ASR 9900 Series
ASR-9010-DC-V2
ASR-9010-SYS
ASR-9006-DC-V2
ASR-9006-SYS
ASR-9922-DC
ASR-9922
ASR-9912-DC
ASR-9912
PWR-6KW-AC-V3=
A9K-AC-PEM-V3=
PWR-3KW-AC-V2=
A9K-AC-PEM-V2=
PWR-4.4KW-DC-V3=
A9K-DC-PEM-V3=
PWR-2KW-DC-V2=
ASR-9010-FAN-V2
ASR-9006-FAN-V2
ASR-9922-FAN-V2
ASR-9922-FAN-V3
A9K-9912-FAN
A9K-9904-FAN
ASR-9922-FLTR-CV2
ASR-9922-FLTR-LR
ASR-9900-FLTR-LR
Cisco ASR 9006 and ASR 9010
Expand
Cisco ASR 9006 and ASR 9010
ASR 9010: 23 to 122ºF (-5 to 50ºC)
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety
Cisco ASR 9904
Expand
Cisco ASR 9904
Width: 17.57 in. (446.28 mm)
Depth: 25.02 in. (635.51 mm)
Weight:
62 lb (28.2 kg) (V2 PEM AND chassis)
114.05 lb (51.84 kg) (2 RSP, Fan Tray, PEM)
1 fan tray
1 PEM (either DC or AC)
1 fan filter
Feed redundancy
Power-supply redundancy
Route processor redundancy
Software redundancy
21- and 23-in. adapters available
Note: Minimum 17.75-in. opening between posts is needed for proper operation.
Active/active nonblocking operation mode in dual-RSP redundant configuration
Fully redundant in dual-RSP redundant configuration
Built-in service-intelligence and traffic-prioritization capability
Multiple power module types:
3 kW AC power module
2.1 kW DC power module
Note: Mixing of AC and DC modules is not supported
DC: N+1 redundancy
Power module redundancy
A/B Feed redundancy
Fully load-sharing power infrastructure
Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
23 to 122ºF (-5 to 50ºC) for ASR 9910
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety
Cisco ASR 9906 and ASR 9910
Expand
Cisco ASR 9906 and ASR 9910
23 to 122ºF (-5 to 50ºC) for ASR 9910
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety
Cisco ASR 9912 and ASR 9922
Expand
Cisco ASR 9912 and ASR 9922
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety